The Math Behind the MALR

The Moist Adiabatic Lapse Rate is slower than the DALR because condensation releases latent heat. Unlike the DALR, the MALR is not constant — it depends on temperature and moisture. Here's the derivation.

Starting from the DALR

Recall the dry adiabatic relationship (expressed in terms of pressure):

dT/dP = Rd T / (cp P)

For saturated air, we add latent heating. When a parcel rises by dP, some water vapor condenses, releasing latent heat Lv per kilogram of condensate. The amount condensed depends on how the saturation mixing ratio ws changes with pressure.

The Clausius-Clapeyron Connection

The saturation vapor pressure es follows the Clausius-Clapeyron equation:

des/dT = Lv es / (Rv T²)

where Rv = 461.5 J/(kg·K) is the gas constant for water vapor, and Lv ≈ 2.501 × 10&sup6; J/kg is the latent heat of vaporization.

The saturation mixing ratio relates to vapor pressure as:

ws = 0.622 × es / (P - es) ≈ 0.622 × es / P

The Moist Adiabatic Formula

Adding latent heat release to the first law and working through the algebra gives the moist adiabatic lapse rate:

         Rd T       1 + (Lv ws) / (Rd T)
dT/dP = -------- × ---------------------------
         cp P       1 + (Lv² ws) / (cp Rv T²)

The numerator is the DALR multiplied by a factor slightly greater than 1. The denominator is always greater than 1 (and greater than the numerator correction). The net effect: dT/dP for the MALR is always smaller than for the DALR, meaning the parcel cools more slowly per unit of pressure drop.

Why It Varies

The key variable is ws — the saturation mixing ratio. It increases exponentially with temperature (thanks to Clausius-Clapeyron):

  • Warm air (~30°C): ws is large → lots of condensation → lots of latent heat → MALR as low as ~3.5°C/km (~1.5°C per 1,000 ft).
  • Cold air (~-20°C): ws is tiny → barely any condensation → MALR approaches the DALR (~9°C/km).

This is why MALR lines on a Skew-T fan out: the warm ones on the right lean strongly to the right (slow cooling), while the cold ones on the left are nearly as steep as DALR lines.

On the Skew-T

Each teal MALR line on the Skew-T is computed by numerically integrating the formula above, stepping from a starting temperature at 1000 mb upward in small pressure increments. The curvature you see (concave left) reflects the fact that as the parcel cools during ascent, ws drops and the cooling rate gradually approaches the DALR.